BFV83704Z Panasonic frequency converter 380V/37KW
Stable operation, excellent performance, low noise design
1. Safety
· Accident prevention system
(Password-controlled data lock function)
· Passwords are programmed to maintain operational consistency
· Electronic thermal overload protection
2. Operability
· Creating digital parameters on the operator panel is easy
· Advanced monitoring features and space-saving design
· Extremely refined design combined with particularly effective and detailed parameters
· uniquePWMThe control can obtain excellent low-speed torque and control
· Preset15kHzcarrier frequency, ultra-low noise operation
3. Device function
· Wide range of frequency options
· Perfect plus/Reduction function
· Frequency jump characteristics
· Maximum output voltage setting
· Jog operation
· Smooth operation at low frequency
· Overload protection function
· Instantaneous power-off and re-start performance
4. System characteristics
· Operational status feedback
· add/Deceleration is linked to multi-speed operation
· Multiple speed control methods
· DC braking range and time adjustment
· Master-slave (proportional) operation
Standard Specifications:
Applicable to motor output |
Model |
Rated Output Current (A) |
Rated Output Capacity (kVA) |
Power Supply Capacity (kg) |
5.5kW |
BFV80554Z |
12 |
9.6 |
4 |
7.5kW |
BFV80754Z |
17 |
13.5 |
4.2 |
11kW |
BFV81104Z |
22 |
17.5 |
10 |
15kW |
BFV81504Z |
31 |
24.7 |
10 |
19kW |
BFV81904Z |
38 |
30.3 |
13 |
22kW |
BFV82204Z |
43 |
34.3 |
13 |
22kW |
BFV82204Z |
43 |
34.3 |
13 |
30kW |
BFV83004Z |
61 |
48.6 |
20 |
37kW |
BFV83704Z |
70 |
55.8 |
24 |
The standard applies to the motor output |
5.5-37 kW |
Rated output |
Rated voltage |
Three-phase 380-460V |
Overload current rating |
150% of the rated output current for 1 minute |
Input power |
Phase number, voltage, frequency |
Three-phase 380-460V 50/60Hz |
Voltage allows fluctuations |
+10% of rated input AC voltage |
Frequency allows fluctuations |
±5% of rated input frequency |
Instantaneous voltage drop tolerance |
Continue operation at greater than or equal to 330V or below 330V for no more than 15 milliseconds |
Microchip Centennial Electronic Technology - Professional Sensor Expert