BFV81904Z Panasonic inverter 380V/19KW
Stable operation, excellent performance, low noise design
1. Security
· Accident prevention system
(Data lock function controlled by password)
· Passwords are programmed to maintain operational consistency
· Electronic thermal overload protection
2. Operability
· Programming the digital parameters on the operator panel is very simple
· Advanced monitoring features and space-saving design
· Extremely sophisticated design and particularly effective and exhaustive parameters are combined
· uniquePWMControl can obtain excellent low-speed torque and control
· Presetable available15kHzCarrier frequency, ultra-low noise operation
3. Device features
· Wide range of frequency selection
· Perfect plus/Deceleration function
· Frequency leap characteristics
· Maximum output voltage setting
· Jog run
· Low frequencies run smoothly
· Overload protection function
· Instantaneous power off and restart performance
4. System characteristics
· Operational status feedback
· add/Deceleration is linked to multi-speed operation
· Multiple speed control methods
· DC braking range and time adjustment
· Master-slave (scale) runs
Standard Specifications:
Suitable for motor output
|
Model
|
Rated output current(A)
|
Rated Output Capacity (kVA)
|
Power capacity(kg)
|
5.5kW
|
BFV80554Z
|
12
|
9.6
|
4
|
7.5kW
|
BFV80754Z
|
17
|
13.5
|
4.2
|
11kW
|
BFV81104Z
|
22
|
17.5
|
10
|
15kW
|
BFV81504Z
|
31
|
24.7
|
10
|
19kW
|
BFV81904Z
|
38
|
30.3
|
13
|
22kW
|
BFV82204Z
|
43
|
34.3
|
13
|
22kW
|
BFV82204Z
|
43
|
34.3
|
13
|
30kW
|
BFV83004Z
|
61
|
48.6
|
20
|
37kW
|
BFV83704Z
|
70
|
55.8
|
24
|
Standard applies to motor output
|
5.5-37 kW
|
Rated output
|
Rated voltage
|
Three-phase 380-460V
|
Overload current rating
|
150% of rated output current for 1 minute
|
Enter the power supply
|
Number of phases, voltage, frequency
|
Three-phase 380-460V 50/60Hz
|
Voltage fluctuations are allowed
|
+10% of rated input AC voltage
|
Frequency allows fluctuations
|
±5% of rated input frequency
|
Instantaneous voltage drop tolerance
|
Continue operation when greater than or equal to 330V or less than 330V and not more than 15 milliseconds
|