CH402 RKC CH402 Full Input Intelligent PID Temperature Control Instrument Thermostat Output 4~20ma
Product Introduction:
This product is a new type of temperature controller, which can implement high-precision control and is the most reasonable price. The large LED display is suitable for reading data from a distance, it is easy to monitor the temperature status, and the standard models are equipped with the latest self-correction function, which can automatically correct the PID constant. Functions such as temperature alarm, heater disconnection alarm (3-phase heater available), control ring disconnection alarm, etc. are available.
main structure and function
* Self-correction function
* Large screen LED display
* Heating/Cooling Control *
* Digital Communication *
* Temperature Alarm*
Heater Disconnection Alarm*
Control ring disconnection alarm* //www.chip100.com/ specifications and models:
CH102 (48×48×100mm)
CH402 (48×96×100mm)
CH902 (96×96×100mm)
CD401 (48×96×100mm)
CD501 (96×48×100mm)
CD701 (72×72×100mm)
CD901 (96×96×100mm)
Selection table
CB/CH/CD |
□ |
□□□ |
- |
□ |
□ |
* |
□ |
□ |
- |
□ |
□ |
Control mode
PID control and automatic calculation reverse action
PID control and automatic calculation positive action)
Heating/cooling PID control and automatic calculation, water cooling*1
Heating/cooling PID control and automatic calculation, air cooling*1
|
F
D
W
A |
|
|
|
|
|
|
|
|
|
|
Input See Input Table Range
|
□□□ |
|
|
|
|
|
|
|
|
|
Output 1
Relay contact output
Voltage pulse output
Current output
The trigger output for the drive of the thyristor control tube
The thyristor control tube output
|
|
M
V
8
G
T |
|
|
|
|
|
|
|
Output 2
Relay point power output
Voltage pulse output
Current output
The thyristor control tube output
|
|
M
V
8
T |
|
|
|
|
|
|
alarm
Alarm 1 See Alarm Form 1
Second alarm See the second alarm table
|
|
□ |
□ |
|
|
|
communication
Not provided
RS—485
|
|
N
5 |
|
Water and dust resistance
Not provided
Water and dust resistant
|
|
|
N
1 |
Enter the range table
hot
electricity
idol
|
input
|
Scope
|
code
|
Scope
|
code
|
Scope
|
code
|
K(JIS/IEC) |
0~200℃
0~800℃
0~1372℃ |
K01
K04
K07 |
0~400℃
0~1000℃
0~100℃ |
K02
K05
K13 |
0~600℃
0~1200℃
0~300℃ |
K03
K06
K14 |
J(JIS/IEC) |
0~200℃
0~800℃ |
J01
J04 |
0~400℃
0~1000℃ |
J02
J05 |
0~600℃
0~1200℃ |
J03
J06 |
R #1 |
0~1600℃ |
R01 |
0~1769℃ |
R02 |
0~1350℃ |
R04 |
S #1 |
0~1600℃ |
S01 |
0~1769℃ |
S02 |
|
|
B #1 |
400~1800℃ |
B01 |
0~1769℃ |
B02 |
|
|
E |
0~800℃ |
E01 |
0~1000℃ |
E02 |
|
|
N |
0~1200℃ |
N01 |
0~1300℃ |
N02 |
|
|
T #2 |
-199.9~400.0℃
0~350.0℃ |
T01
T04 |
-199.9~100.0℃ |
T02 |
-100.0~200.0℃ |
T03 |
W5Re/W26Re(ASTM) |
0~2000℃ |
W01 |
0~2320℃ |
W02 |
|
|
PL2(NBS) |
0~1300℃ |
A01 |
0~1390℃ |
A02 |
0~1200℃ |
A03 |
U(DIN)#2 |
-199.9~600℃ |
U01 |
-199.9~100℃ |
U02 |
0.0~400.0℃ |
U03 |
L(DIN) |
0~400℃ |
L01 |
0~800℃ |
L02 |
|
|
hot
electricity
obstruct
|
Pt100(JIS/IEC |
-199.9~649℃
-100~100.0℃
0.0~100.0℃
0.0~500.0℃ |
D01
D04
D07
D10 |
-199.9~200.0℃
-100~200℃
0.0~200℃ |
D02
D05
D08 |
-100~50.0℃
0.0~50.0℃
0.0~300.0℃ |
D03
D06
D09 |
JPt100(JIS) |
-199.9~649℃
-100.0~100.0℃
0.0~100.0℃
0.0~500.0℃ |
P01
P04
P07
P10 |
-199.9~200.0℃
-100~200℃
0.0~200℃ |
P02
P05
P08 |
-100~50.0℃
0.0~50.0℃
0.0~300.0℃ |
P03
P06
P09 |
Voltage current
|
0~5V
1~5V
0~20mA #3
4~20mA #3 |
0.0~100.0
0.0~100.0
0.0~100.0
0.0~100.0 |
401
601
701
801 |
|
|
|
|
First Alarm Meter {ALM1} (Built-in Standard)
A: Upper limit deviation alarm G: Upper and lower limit deviation alarm with standby
B: Lower limit deviation alarm H: Upper limit input value alarm
C: Upper and lower limit deviation alarm J: Lower limit input value alarm
D: Alarm in range K: Alarm with upper limit of standby input value
E: Alarm with upper limit of standby deviation L: Alarm with input value of lower limit of standby
F: With standby lower limit deviation alarm R: Control ring disconnection alarm*2
Control output
Relay Contacts AC250V 3A (Resistive)
Logic voltage DC 0/5V
Zero crossing trigger pulse: photocouple triac output 1A 600V
Phase-shifting trigger pulse: photocouple triac output 1A 600V
0-10mA, 0-20mA, 4-20mA current output (load resistance value 600Ω or less)
Alarm type
Upper limit alarm, lower limit alarm, upper limit alarm, lower limit alarm
Transmit output
0-10mA、4-20mA、0-5V、1-5V
Communication interface
RS485
Power output
DC24V (for two-wire transmitters)
Operating power supply
AC85-264V 50/60Hz
Dimensions
(W x H x D)
48 X 96 X 100mm
Cut-out size
45+1 X 92+1 mm