| Detection method
              | 
            Opposite type | 
             Regressive reflex type | 
            Diffusion reflection type | 
        
|  project | 
             NPN output | 
            E3F3-T11 | 
            E3F3-R11 | 
            E3F3-R12 | 
            E3F3-D11 | 
            E3F3-D12 | 
        
| E3F3-T16 | 
            E3F3-R16 | 
            E3F3-R17 | 
            E3F3-D16 | 
            E3F3-D17 | 
        
| E3F3-T61 | 
            E3F3-R61 | 
            E3F3-R62 | 
            E3F3-D61 | 
            E3F3-D62 | 
        
| E3F3-T66 | 
            E3F3-R66 | 
            E3F3-R67 | 
            E3F3-D66 | 
            E3F3-D67 | 
        
|  PNP output | 
            E3F3-T31 | 
            E3F3-R31 | 
            E3F3-R32 | 
            E3F3-D31 | 
            E3F3-D32 | 
        
| E3F3-T36 | 
            E3F3-R36 | 
            E3F3-R37 | 
            E3F3-D36 | 
            E3F3-D37 | 
        
| E3F3-T81 | 
            E3F3-T81 | 
            E3F3-T82 | 
            E3F3-T81 | 
            E3F3-T82 | 
        
| E3F3-T86 | 
            E3F3-T86 | 
            E3F3-T87 | 
            E3F3-T86 | 
            E3F3-T87 | 
        
|  Detection distance | 
             5M | 
             3M (without M.S.R function) | 
            2M (with M.S.R function) | 
             0.1M | 
             0.3M | 
        
| (When using E39-R1) | 
            (When using E39-R1) | 
        
|  Standard detection objects | 
             Opaque object: 11mm min | 
             Opaque objects: 56mm min | 
             100×100mm white drawing paper | 
        
|  Respond to the difference | 
             -- | 
             less than 20% of the detection distance | 
        
|  Light Source (Wavelength) | 
             Infrared LED | 
             Red LED | 
             Infrared LED | 
        
|  Supply voltage | 
             DC 12~24V± 10% (p-p) less than 10% | 
        
|  Current consumption | 
             DC :45mA Max | 
             DC :25mA Max | 
        
|  Control output | 
             Load supply voltage DC 26.4V or less, load supply current 100mA or less (residual voltage 1V or less) | 
        
|  Protection circuit | 
             Power reverse/output short circuit | 
        
|  Response time | 
             Action/reply Each is less than 1.0ms | 
        
|  Sensitivity adjustment | 
             not | 
             Yes | 
        
|  Ambient lighting | 
             Incandescent lamp below 3000lx/daylight below 10000lx | 
        
|  Ambient temperature | 
             When operating: -25~+55°C(with no icing) When saving:-30~+70°C(with no icing) | 
        
|  Ambient humidity | 
             When acting: 45%~85% (with no icing) RH When saving: 35%~95% (with no icing) RH | 
        
|  Insulation resistance | 
             20MΩ or more (500VDC) | 
        
|  Dielectric strength | 
             AC1000V or more at 50/60Hz, between the current-bearing part and the housing for 1 minute | 
        
|  Vibration resistance (durable) | 
             10~55Hz, 1.5mm double width, up to 1h in the X, Y, and Z directions | 
        
|  Impact resistance (durable) | 
             500m/s2 double width, 3 times each in the X, Y, and Z directions | 
        
|  Protect the structure | 
             IEC60529 IP66 | 
        
|  Connection | 
             Wire Lead Type (Standard Wire Length: 2m) / M12 Connector | 
        
|  Light | 
             Action indicator (orange) [Power indicator for floodlight (orange)] | 
        
|  weight | 
             Wire type | 
             Metal housing: 200gMAX | 
             Metal Case: 100g MAX | 
        
|  Plastic case: 170g MAX | 
             Plastic case: 85g MAX | 
        
|  Connecting head type | 
             Metal case: 120g MAX | 
             Metal case: 60g MAX | 
        
|  Plastic case: 40g MAX | 
             Plastic case: 20g MAX | 
        
|  Packing method | 
             Nylon bag | 
        
|  material | 
             enclosure | 
             ABS or BRASS | 
        
|  lens | 
             PMMA |