Detection method |
Opposite type
|
Regressive reflex type
(M.S.R. with reflector)
|
Diffusion reflection type |
type
Item No |
NPN output |
E3Z-T61(K)
E3Z-T66
|
E3Z-T62
E3Z-T67
|
E3Z-T61A
E3Z-T66A |
E3Z-R61/R66 |
E3Z-R61K |
E3Z-D61(K)/D66 |
E3Z-D62(K)/D67 |
PNP output |
E3Z-T81(K)
E3Z-T86
|
E3Z-T82
E3Z-T87
|
E3Z-T81A
E3Z-T86A |
E3Z-R81/R86 |
E3Z-R81K |
E3Z-D81(K)/D86 |
E3Z-D82(K)/D87 |
Detection distance |
15m |
30m |
10m |
4m [100mm] * (when using E39-R1S) 3m [100mm] * (when using E39-R1) |
3m [150mm] * (when using E39-R1S) 2m [100mm] * (when using E39-R1) |
100mm
(Blank paper.)
100×100mm) |
1m
(Blank paper.)
300×300mm) |
Beam diameter |
—— |
Standard detection objects |
Opaque objects of φ12mm or more |
Opaque objects of φ75mm or more |
—— |
Minimal detection of objects |
—— |
Respond to the difference |
—— |
The detection distance is less than 20% |
pointing angle |
Projector and receiver: 3~15° each |
2~10° |
—— |
Light source (luminous wavelength)
|
Infrared photodiode
(870nm)
|
Red LED (660nm)
|
Red light-emitting diode
(660nm)
|
Infrared light secondary tube
(860nm) |
Supply voltage |
DC12~24V± 10% fluctuation (p-p) less than 10% |
Current consumption
|
Floodlight: 15mA
Receiver: 20mA |
30mA or less |
Control output |
Load supply voltage DC26.4V or less, load supply current below 100mA Residual voltage Load current 10mA or less: less than 1V Load current 10~100mA: less than 2V
Open collector output (NPN/PNP output varies by model)
ON/ON switch switch when light is in and on when light is blocked |
Protection circuit |
Power supply reverse connection protection, output short circuit protection |
Protect power supply reverse connection protection, output short circuit protection, mutual interference prevention function, output reverse connection protection |
Answer time |
Action and reset: less than 1ms each |
Sensitivity adjustment |
One-way rotary button |
illuminating |
Illuminance of the light surface: incandescent lamp: less than 3,000 lx, sunlight: less than 10,000 lx |
ambient temperature |
During operation: -25~+55°C, when stored: -40~+70°C (no freezing, condensation) |
ambient humidity |
When acting: 35~85%RH, when saving: 35~95%RH (non-freezing) |
Insulation resistance |
20MΩ or more (DC500V megaohmmeter) |
Withstand voltage |
AC1,000V 50/60Hz 1min |
Vibration resistance (durable) |
10~55Hz dual amplitude 1.5mm X, Y, Z directions for 2h |
Impact resistance (durable) |
500m/s2 3 times in each direction of X, Y and Z |
Protect the structure |
IEC IP67 (Oil-proof type: IEC IP67 (excluding JEM IP67f wires and connectors)) |
Connection |
Lead Cord (Standard Length 2m/500mm) / M8 Connector Type / M8 Connector Relay Type (Oil-proof Type) |
Light |
Action indicator light (orange) Stabilization indicator light (green) [but the floodlight is a power indicator light (orange)] |
quality
(Bundle Status) |
The wire leads
Type 2m |
Approx. 120g |
Approx. 65g |
Connector type |
About 30g |
Approx. 20g |
M8 connector
Relay format
|
About 50g |
About 30g |
Material |
enclosure |
Polybutylene terephthalate |
Lens section |
Polyester composite rubber |
Methyl propylene resin |
Polyester composite rubber |
annex |
Instruction manual, Note: Regression reflector, installation metal accessories sold separately |