Item model |
F3WN-X□□□□N14 |
F3WN-X□□□□N25 |
F3WN-X□□□□N40 |
F3WN-X□□□□N70 |
Detection distance |
0.2~7m |
0.2~10m |
Optical axis spacing (p) |
9mm |
15mm |
30mm |
60mm |
Optical axis number |
17、27 |
11~119 |
6~60 |
5~30 |
Detection Width (PH) |
153 243mm(PH=n×P) |
187~1,807mm(PH=(n—1)×P+37) |
187~1,807mm(PH= (n—1)×P+37) |
277~1,777mm(PH= (n—1)×P+37) |
Minimal detection of objects |
The diameter of the opaque body is φ14mm |
The diameter of the opaque body is φ25mm |
The diameter of the opaque body is φ40mm |
The diameter of the opaque body is φ70mm |
Light source (luminous wavelength) |
Infrared Light Emitting Diode (870nm) |
Supply voltage |
DC24V±10% pulse (p-p) less than 10% |
Current Consumption (No Load) |
floodlight |
Up to ~50 optical axes: 140 mA or less, 51~85 optical axes: 155 mA or less, 86 optical axes or higher: 170 mA or less |
Receiver |
~50 optical axes: 100mA or less, 51~85 optical axes: 110mA or less, 86 optical axes and above: 120mA or less |
Control output |
Load supply voltage DC 24V or less, NPN transistor output (load current 50mA or less) Control output 1: ON when light enters Control output 2: ON when shading *Selection of output line is set |
External diagnostic function |
External diagnostic input line 0~1.5V: Flooding stop (short-circuit current 3mA or less) When the external diagnostic input line is open or 9~24V: Normal beaming |
Display light |
floodlight |
Illumination level indicator light 5 LEDs (green): Illuminates according to light exposure Error mode display light 3 LEDs (red): Illuminates according to what occurred in the event of an abnormality Power indicator light (green): Normally on, turns off when an abnormality occurs External diagnostic indicator light (orange): Lights up when external diagnostics occur |
Receiver |
Illuminated Level Indicator Light 5 LEDs (Green): Illuminates according to the amount of light received Error Mode Indicator Light 3 LEDs (Red): Illuminates according to the occurrence in the event of an abnormality Control Output 1 Action Indicator Light (orange): Illuminates when light enters Control Output 2 Action Indicator Light (orange): Illuminates when shading Power Indicator Light (green): Normally on, turns off when an abnormality occurs Function Display Light (Green): Open |
Protection circuit |
Power supply reverse connection protection, output short circuit protection |
Answer time |
For details, please refer to page 707 of → |
Use ambient illumination |
Incandescent lamp: 3,000 lx or less, sunlight: 10,000 lx or less |
ambient temperature |
During operation: -10~+55°C, when stored: -30~+70°C (no freezing or condensation) |
ambient humidity |
When acting/saving: 30~95% RH each (non-condensing) |
Insulation impedance |
20MΩ or more (DC500V megaohmmeter) |
Withstand voltage |
AC1,000V 50/60Hz 1min |
Vibration (malfunction) |
durable |
10~55Hz re-vibration 1.5mm X, Y, Z directions for 2h |
Malfunction |
10~55Hz re-vibration 0.7mm in all directions of X, Y, and Z for 50min |
Impact (Malfunction) |
durable |
300m/s2 3 times in each direction of X, Y, and Z |
Malfunction |
100m/s2 1,000 times in each direction of X, Y, and Z |
Protect the structure |
IEC specification IP65 |
Connection |
M12 connector internal |
Quality (Bundle Status) |
The following formula is calculated: Mass (g) = (Detection width +100) ×2 + 1,300 Mass (g) = (Detection width + 100) × 2 + 1,700 Mass (g) = (Detection width +100) 2 + 1,700 Mass (g) = (Detection width +100) × 2 + 2,100 with a detection width of 1,417~1,822 mm = (Detection width + 100) 2 + 2,100 |
Material |
enclosure |
aluminium |
Front cover |
Propyl dilute (PMMA resin) |
line |
Oil-resistant PVC |
accessory |
Metal mounting accessories (upper and lower), metal mounting accessories (middle) (depending on the total length of the sensor), a set of mounting screws, and an instruction manual |