Rating/Performance
noumenon The sensor department F3ZN-S□□□□N□□-(01~05) is common
Item model |
F3ZN-S□□□□N09 |
F3ZN-S□□□□N15 |
F3ZN-S□□□□N30 |
F3ZN-S□□□□N60 |
Detection distance |
0.2~7m |
0.2~10m |
Optical axis spacing |
9mm |
15mm |
30mm |
60mm |
Number of optical axes |
21~125 |
13~120 |
7~60 |
4~30 |
Detects width |
180~1,116mm |
180~1,785mm |
180~1,770mm |
240~1,740mm |
Minimum detection object (opaque body) |
Diameter φ14mm |
Diameter φ25mm |
Diameter φ40mm |
Diameter φ70mm |
Light source (luminous wavelength) |
Infrared LED (870nm) |
Supply voltage |
DC24V± 10% pulse (p-p) less than 10%. |
Current consumption |
Photoprojector: 170mA or less, light receiver: 120mA or less |
Control the output |
Load supply voltage DC24V or less, NPN transistor output (load current 50mA or less) Control output 1: ON when entering light, control output 2: ON when shading (factory initial setting) |
External diagnostic capabilities |
External diagnostic input line 0~1.5V: Projection stop (short-circuit current 3mA or less) External diagnostic output line open or 9~24V: Usually projected |
Display light |
Light projector |
Light level display light 5 LEDs (green): light up according to the amount of light received Error mode display light 3 LEDs (red): When an abnormality occurs, the light is lit according to the content of the event Power display light (green): usually on and off when an abnormality occurs External diagnostic display light (orange): On when external diagnostics |
Light receiver |
Light level display light 5 LEDs (green): light up according to the amount of light Error mode display light 3 LEDs (red): When an abnormality occurs, the light is lit according to the content of the event Control output 1 action display light (orange): When the light is in, the light is turned on Control output 2 action display light (orange): when the light is blacked, the light is on (initially set at the factory) Power display light (green): usually on the light, turn off when an abnormality occurs Function display light (green): set to light on when it is open |
Protection circuits |
Power supply reverse connection protection, output short circuit protection |
Response time |
See page 683 of → for details |
Use ambient temperature |
Light-receiving surface illumination incandescent lamp: 3,000lx or less, sunlight: 10,000lx or less |
Ambient temperature |
During operation: -10~+55°C, when storing: -30~+70°C (no freezing, dew) |
Ambient humidity |
When moving and storing: 30~95% RH each (no condensation) |
Insulation resistance |
20MΩ or more (DC500V megohmmeter) |
Withstand voltage |
AC1,000V 50/60Hz 1min |
Vibration (malfunction) |
10~55Hz complex amplitude 0.7mm 20 scans in all directions of X, Y, Z |
Shock (malfunction) |
100m/s2 1,000 times in all directions of X, Y, Z |
Protect the structure |
IEC specification IP65 |
Connection method |
M12 connector in-form |
Quality (bale status) |
Mass (g) = (detection width + 100) × 2 + 2,100 |
Material |
enclosure |
aluminium |
Front cover |
Acrylic (PMMA resin) |
line |
Oil resistant PVC |
accessory |
Metal mounting fittings (top/bottom), metal mounting fittings (middle)*, instruction manual |
* The middle metal fittings are only attached to the following inner type. The total length is 640~1,280mm or less, and there is 1 set attached; Total length over 1,280mm: 2 sets attached noumenon Controller Department
Item model |
F3ZP-M1N-FLK |
Supply voltage |
DC24V± 10% pulse (p-p) less than 10%. |
Current consumption |
50mA or less (excluding sensor consumption current, output current) |
Connect the sensor |
F3ZN-S□□□□N□□ |
Number of sensor connections |
1 set (3 sets or up to 240 optical axes maximum: Recently) |
OUTPUT[OUT1·2, OUTPUT(OUT3, ERROR, BANK OUT, TCHOUT)] |
Load supply voltage DC24V or less, NPN open connector output (load current 50mA or less) |
Input (TCH, EDI, RESET, BANKIN, BANK1, BANK2) |
DC input maximum input voltage: 24V±10% Action voltage ON voltage: minimum 9V/OFF voltage: maximum 1.5V, input current below 3mA |
Input and exit of programmable sequence |
(D00~D15) The purpose of use differs depending on the application. Output: load supply voltage DC24V or less, NPN open connector output (load current 50mA or less) Input: DC input voltage: 24V±10% input current 3mA or less Action voltage ON voltage: min. 9V/OFF voltage: max. 1.5V |
Communication capabilities |
Communication port |
RS-232C □ (D-SUB 9 pin connector), RS-485 □ (terminal block) (either side can be selected with a transfer switch) |
Communication procedures |
CompoWay/F |
No. |
00~15 (set with rotary switch) |
Communication speed |
9600, 14400, 19200, 38400, 57600, 115200bps (switching conversion) |
data structure |
Data bit 7, parity, start bit 1, start bit 2, no traffic control |
Time function |
Year/Month/Day/Hour/Minute/Second/Week |
Display light |
POWER: Green, MODE: Green, RUN: Green: ERROR: Red |
Protection circuits |
Power supply reverse connection protection, output short circuit protection |
Response time |
See page 683 of → for details |
Ambient temperature |
When using: -10~+55°C, when storing: -20~+75°C (no freezing, condensation) |
Ambient humidity |
When using and storing: 10~90%RH (no condensation) |
Insulation resistance |
Count 20MΩ or more (DC500V megohmmeter) Full terminal - housing room |
Withstand voltage |
AC1,000V 50/60Hz 1min leakage current 10mA or less |
Vibration (durable) |
Reference JIS C0041 10~57Hz Amplitude 0.075mm 57~150Hz acceleration 9.8m/s2 80min in all directions of X, Y, Z (8min when scanning× 10 scans = 80min in total) |
Impact (durable) |
Refer to JIS C0041 147m/s2 3 times in the X, Y, and Z directions |
structure |
Built-in disc type |
accessory |
RS-232C connector (latch, hood), instruction manual |
|