project |
Standard type |
High capacity type |
Contact resistance |
100 mΩ or less |
Action time |
15 ms or less (AC coil type: 20 ms or less) |
Reset time |
5 ms or less (AC coil type: 20 ms or less) |
The maximum value of the switching frequency |
Mechanical: 18,000 times/h Electrical: 1,800 times/h (under rated load) |
Insulation resistance |
1,000 MΩ or more (DC 500 V) |
Insulation resistance |
AC 1,000 V, 50/60 Hz 1 min between copole contacts
AC 6,000 V, 50/60 Hz between coil and contact 1 min |
Pressure resistance |
10,000 V between coil and contact, 1.2×50 μs |
vibration |
Malfunction: 10 ~ 55 ~10 Hz, double amplitude 1.5-mm
Durability : 10~55~10 Hz, dual amplitude 1.5-mm |
impact |
Malfunction: 1,000 m/s2 (approx. 100 g)
Durability: 100 m/s2 (approx. 10 g) |
life span |
Mechanical: 10,000,000 cycles or more (18,000 cycles/h) |
electric
More than 50,000 times
AC 250 V 5 A (NC)
DC 24 V 5 A (NC)
More than 100,000 times
AC 250 V 12 A (NO)
DC 24 V 12 A (NO) |
electric
More than 50,000 times
AC 250 V 5 A (NC) ( For AC coil type only)
DC 24 V 5 A (NC) ( AC coil type only)
Over 50,000 cycles AC 250 V 16 A (NO)
DC 24 V 16 A (NO)
More than 100,000 times
AC 250 V 12 A (NO) ( DC coil type only) |
Use ambient temperature |
-40°C~70°C (AC coil type), -40°C~85°C (DC coil type) |
Use ambient humidity |
5%~85% |
weight |
About 10g |