project |
classify |
Monostable |
1. Winding locking type |
2. Winding locking type |
Contact resistance*1 |
50mΩ or less |
Action (positioning) time*2 |
5ms or less (about 2.9ms, but.)
DC48V coil approx. 2.4ms) |
5ms or less (approx. 2.3ms) |
Reset (reset) time*2 |
5ms or less (approx. 1.3ms) |
5ms or less (approx. 2.3ms) |
Minimum placement pulse amplitude |
- |
15ms |
Minimum reset pulse amplitude |
- |
15ms |
Insulation resistance*3 |
1,000MΩ or more (DC 500V MHz meter) |
Shock voltage resistance |
between the coil contacts |
2,500V 10×160 (μs) (FCC part68 standard) |
between the same pole contact points |
1,500V 10×160(μs) (FCC part68 standard) |
Pressure resistance |
between the coil contacts |
AC1,500V 50/60Hz 1min |
between the same pole contact points |
AC1,000V 50/60Hz 1min |
vibration |
durable |
10~55~10Hz Single Amplitude 2.5mm (Dual Amplitude 5mm) |
Malfunction |
10~55~10Hz Single Amplitude 1.65mm (Dual Amplitude 3.3mm) |
impact |
durable |
1,000m/s2 |
Malfunction |
300m/s2 |
life span |
machine |
100 million times (switching frequency 36,000 times/h) |
electric |
More than 100,000 times (rated load AC125V 0.4A resistive load, AC125V 0.2A inductive load) (switching frequency 1,800 times/h) |
More than 500,000 times (rated load DC 30V 2A resistive load, DC30V 1A inductive load) (switching frequency 1,800 times/h) |
More than 200,000 times (DC 30V 3A resistive load) (Switching frequency 1,800 times/h) |
Failure rate P level (reference value*4) |
DC10mV 10μA |
Use ambient temperature |
-40~+70°C (no freezing, no condensation) |
Use ambient humidity |
5~85%RH |
weight |
Approx. 2.7g |