Ratings / Performance
■Rated value
● Operating coil
Model
Rated voltage
Current Rating (mA)
Coil Resistance (Ω)
Operating Voltage (V)
Reset Voltage (V)
Maximum continuous
Allowable Voltage (V)
Power Consumption (mW)
DC24V
4 poles : 15
6 poles: 20.8
4 poles : 1,600
6 poles: 1,152
Below 75%
More than 10%
110%
4 poles : about 360
6 poles: about 500
Note 1. The rated current, the coil resistance is the value at the coil temperature of +23°C, and the tolerance is ±15%.
Note 2. The operating characteristics are the value at the coil temperature of +23°C.
Note 3. The maximum continuous allowable voltage is the maximum value when the operating ambient temperature is +23°C.
●Switch section (contact section)
load
project
Resistive loads
Rated load
AC250V 6A
DC30V 6A
Rated current current
6A
The maximum value of the contact voltage
AC250V、DC125V
The maximum value of contact current
6A
■ Characteristics of safety relay socket model
Continuous energized current
Pressure resistance
Insulation resistance
P7SA-14□
6A *1
Between poles : AC2,500V 1min
1,000Ω or more*2
*1. P7SA-1□F In the environment of +55~+85°C continuous current current 6A, please reduce it by 0.1A/°C.
*2. Measurement conditions: Measured with a DC500V megaohm meter, the measurement part is the same as the withstand voltage item.
Note: P7SA-1□F-ND (DC24V) should be used in an ambient temperature of -25~+55°C.
■Performance contact resistance *1
Below 100mΩ
Action time *2
20ms or less
Response time *3
10ms or less
Reset time *2
20ms or less
Max switch
frequency
mechanical
36,000 times/h
Rated load
1,800 times/h
Insulation resistance *4
1,000 MΩ or more
Withstand pressure *5 *6
vibration
10~55~10Hz Single amplitude 0.75mm (complex amplitude 1.5mm
impact
durable
1,000m/s2
Malfunction
100m/s2
Lifespan *7
mechanical
More than 10 million times (switching frequency 36,000 times/h)
Electrical
More than 100,000 times (rated load, switching frequency 1,800 times/h)
Failure rate P level (reference value*8)
DC5V 1mA
Ambient temperature *9
-40~+85°C (no freezing or condensation)
Use ambient humidity
5~85%RH
quality
4 poles: about 22g, 6 poles: about 25g
*1. Measurement conditions: DC5V1A voltage reduction method.
*2. Measurement conditions: rated voltage operation
Ambient temperature conditions: +23°C
Vibration time is not included.
*3. The response time is after the coil voltage is turned off until the contact is turned off
Time.
Measurement conditions: rated voltage operation
Ambient temperature conditions: +23°C
*4. Measurement conditions: Use a DC500V megaohm meter to measure, and measure the part and
The withstand voltage item is the same.
*5. 3 poles represent 31-32 or 33-34, 4 poles represent 43-44, 5 poles represent 53-
54, 6 poles represent 63-64.
*6. When using the socket (P7SA), the coil contact-to-contact/anode is AC2,500V
50/60Hz 1min。
*7. The durability conditions are ambient temperature +15~+35°C and ambient humidity 25
~75% RH.
*8. This value is the value at the switching frequency of 300 times/min.
*9. When working between 70 ~ 85 °C, the rated current is 70 °C or less
When on, reduce by 0.1A/°C (6A at 70°C or lower).
Note. The left side is the initial value.
Product specifications are for reference only, please contact the salesman for details. |