lose enter | Pressure range | | XT | XTL/XT |
0.35 | 0.7 | 1.7 | 3.5 | 7 | 17 | 35 | 70 | 140 Bar |
5 | 10 | 25 | 50 | 100 | 250 | 500 | 1000 | 2000Psi |
Working mode | Absolute, gauge, sealed gauge, differential pressure |
Overload pressure | 2 times the rated pressure up to 3000psi (210Bar) |
Rupture pressure | 3 times rated pressure up to 5000psi (350bar) |
Pressure medium | XT Series: All non-conductive, non-corrosive liquids and gases XTL Series: Any medium compatible with SiO2 and 15-5PH stainless steel |
Rated excitation voltage | 10VDC/AC |
Maximum excitation voltage | 15VDC/AC |
Input impedance | 1000Ω (min) |
lose go out | Output impedance | 1000Ω (nominal) |
Full-scale output (FSO) | 100mV (nominal) |
Zero imbalance | ±5mV (typical) |
Combined nonlinearity and hysteresis | 0.1% FS BFSL (typical) |
Resolution | Infinitesimal |
Natural frequency (kHz) (typical) | 250 | 350 | 400 | 500 | 600 | 750 | 1000 | 1200 | 1400 |
Acceleration sensitivity %FS/g | vertical |
1.0×10-3
|
6.0×10-4
|
3.0×10-4
|
1.5×10-4
|
1.0×10-4
|
5.0×10-5
|
3.0×10-5
|
2.0×10-5
|
1.5×10-5
|
Transverse |
4.0×10-4
|
1.2×10-4
|
6.0×10-5
|
3.0×10-5
|
2.0×10-5
|
1.0×10-5
|
6.0×10-6
|
4.0×10-6
|
3.0×10-6
|
Insulation resistance | ≥100MΩ at 50VDC |
Environmental conditions | Operating temperature range | -55°C to 175°C (-65°F to 350°F) |
Compensate for temperature range | 25°C to 80°C (80°F to 180°F) can be required in any 100°F range within the operating range |
Hot zero point drift | ±1% FS /100°F (typical) |
Thermally sensitive drift | ±1% FS /100°F (typical) |
Steady-state acceleration | ≤10 000g |
Linear vibration | 10-2000Hz sine wave, ≤100g |
Physical properties | Electrical connection | 4 x 30AWG shielded wires, 30 inches long |
weight | 4 g (nominal), excluding wires |
Sensitivity principle | Wheatstone bridge dielectric insulated silicon stacked silicon (leadless technology XTL) |
Installation torque | Up to 15 inches. pound |