lose enter | Pressure range | | XTE | XTEL/XTE |
0.35 | 0.7 | 1.7 | 3.5 | 7 | 17 | 35 | 70 | 140 Bar |
5 | 10 | 25 | 50 | 100 | 250 | 500 | 1000 | 2000psi |
Working mode | Absolute, gauge, sealed gauge, differential pressure |
Overload pressure | 2 times the rated pressure up to 3000psi (210Bar) |
Rupture pressure | 3 times rated pressure up to 5000psi (350bar) |
Pressure medium | XT West Series: All non-conductive, non-corrosive liquids and gases XTL Series: Anything with SiO2and 15-5PH stainless steel compatible media |
Rated excitation voltage | 10VDC/AC |
Maximum excitation voltage | 15VDC/AC |
Input impedance | 1000Ω (min) |
lose go out | Output impedance | 1000Ω (nominal) |
Full-scale output (FSO) | 100mV (nominal) |
Zero imbalance | ±5mV (typical) |
Combined nonlinearity and hysteresis | 0.1% FS BFSL (typical) |
Resolution | Infinitesimal |
Natural frequency (kHz) (typical) | 250 | 350 | 400 | 500 | 600 | 750 | 1000 | 1200 | 1400 |
Acceleration sensitivity %FS/g | vertical | 3.0×10-4
|
3.0×10-4
|
3.0×10-4
|
1.5×10-4
|
1.0×10-4
|
5.0×10-5
|
3.0×10-5
|
2.0×10-5
|
1.5×10-5
|
Transverse
|
6.0×10-5
|
6.0×10-5
|
6.0×10-5
|
3.0×10-5
|
2.0×10-5
|
1.0×10-5
|
6.0×10-6
|
4.0×10-6
|
3.0×10-6
|
Insulation resistance
|
≥100MΩ (Test condition 50VDC)
|
Environmental conditions
|
Operating temperature range
|
-55°C to 273°C (-65°F to 525°F)
|
Compensate for temperature range
|
25°C to 232°C (80°F to 450°F)
|
Hot zero point drift
|
±1% FS /100°F (typical)
|
Thermally sensitive drift
|
±1% FS /100°F (typical)
|
Steady-state acceleration
|
≤10 000g
|
Linear vibration
|
10-2000Hz sine wave, ≤100g
|
Physical properties
|
Electrical connection
|
4 x 30AWG shielded wires, 30 inches long
|
weight
|
4 g (nominal), excluding components and connecting wires
|
Sensitivity principle
|
Wheatstone bridge dielectric insulated silicon stacked silicon (leadless technology XTEL)
|
Installation torque
|
Up to 15 inches. pound
|