lose
enter
|
Pressure range
|
LQ/LE
|
LL/LLHT/LQ/LE
|
0.7
|
1.7
|
3.5
|
7
|
17
|
35 Bar
|
10
|
25
|
50
|
100
|
250
|
500 Psi
|
Working mode
|
Absolute, gauge, sealed gauge, differential pressure
|
Overload pressure
|
2 times the rated pressure, no change in calibration value
|
Rupture pressure
|
3 times the rated pressure
|
Pressure medium
|
All non-conductive, non-corrosive liquids and gases (LQ/LE)
All with SiO215-5PH stainless steel compatible media (LL/LLHT)
|
Rated excitation voltage
|
5VDC/AC
|
Maximum excitation voltage
|
7.5VDC/AC
|
Input impedance
|
1000Ω (min)
|
lose
go out
|
Output impedance
|
1000Ω (nominal)
|
Full-scale output (FSO)
|
100mV (nominal)
|
Zero imbalance
|
±5mV (typical)
|
synthesis
Nonlinearity, hysteresis, repeatability
|
±0.1%FS BFSL (typical)
|
Resolution
|
Infinitesimal
|
Natural frequency (kHz) (typical)
|
300
|
400
|
500
|
600
|
750
|
1000
|
Acceleration sensitivity
%FS/g
|
vertical
|
7.0 x10-4
|
3.0 x10-4
|
1.5 x10-4
|
1.0 x10-4
|
5.0 x10-5
|
3.0 x10-5
|
Transverse
|
1.4 x10-4
|
6.0 x10-5
|
3.0 x10-5
|
2.0 x10-5
|
1.0 x10-5
|
6.0 x10-6
|
Insulation resistance
|
≥100MΩ at 50VDC
|
Environmental conditions
|
Operating temperature range
|
LQ/LL Series: -55°C to 120°C (-65°F to 250°F)
LE/LLHT Series: -55°C to 235°C (-65°F to 450°F)
|
Compensate for temperature range
|
LQ/LL Series: 25°C to 80°C (80°F to 180°F), any 100°F range within the operating range can be requested
LE/LLHT Series: 25°C to 235°C (80°F to 450°F)
|
Hot zero point drift
|
±1% FS /100°F (typical)
|
Thermally sensitive drift
|
±1% FS /100°F (typical)
|
Steady-state acceleration
|
30 000g maximum
|
Linear vibration
|
10-2000Hz sine wave, 100g max
|
Physical properties
|
Electrical connection
|
4 x 32AWG conductors, 36" long (LE/LLHT series 36AWG flat conductors)
|
weight
|
0.2g (nominal), excluding components and connecting wires
|
Sensitivity principle
|
Wheatstone bridge dielectric insulated silicon stacked silicon (LL/LLHT series leadless technology)
|